Shingle Wind Ratings: What Class F and Class H Mean in South Florida

Shingle bundles staged on a dried-in roof deck before installation

Florida’s residential code ties a shingle’s wind class to the design wind speed for the house, and at 168 mph and up only the top classes qualify: Class F under ASTM D3161 or Class H under ASTM D7158. Miami-Dade and Broward homes are designed for speeds above that line, and those two counties go further. There the shingle needs a product approval, has to pass the High-Velocity Hurricane Zone (HVHZ) wind test, and goes on under stricter installation rules. The rating is the entry ticket. How the shingle is nailed and sealed at the edges decides whether it stays on.

The two wind tests, in plain words

Shingle wrappers in Florida have to be labeled with a wind classification. There are two tests behind those labels:

  • ASTM D3161 is a fan test that blows air across installed shingles. The classes in Florida’s table are D and F, with F the higher one.
  • ASTM D7158 measures how well the shingle’s sealant strip holds against uplift. Its classes are D, G and H, with H the highest.

The Florida Building Code, Residential matches the class to the design wind speed for the house. At the lower end of its table, several classes qualify. From 142 mph up, F is the only D3161 class accepted, and from 168 mph up, H is the only D7158 class accepted.

The HVHZ wind section of the Florida Building Code, Building puts the design wind speed for ordinary homes (Risk Category II) at 175 mph in Miami-Dade and 170 mph in Broward, both inside that top row. Palm Beach County homes use the statewide wind map, and the speed depends on location, so the shingle has to meet the class for that address.

Miami-Dade and Broward add their own rules

Inside the HVHZ, a shingle needs a product approval, has to pass the HVHZ’s own tests for wind resistance (TAS 107) and wind-driven rain (TAS 100), and must go on following the approval and the code’s shingle standard, RAS 115. The code then adds requirements you can check on the job:

  • At least six approved nails per shingle, long enough to go through the plywood by at least 1/8 inch.
  • The starter course, eaves, rakes, valleys and intersections set in an 8-inch-wide bed of approved adhesive or roofing cement.
  • Shingles that overhang the eave and rake drip edge by no more than 1/4 inch.
  • Metal at the perimeter edges and in the valleys.
  • A limit of 33 feet of mean roof height, unless the product approval allows more.

Outside the HVHZ, the residential code requires whatever number of fasteners the manufacturer calls for, and never fewer than four per strip shingle.

What the shingle we install carries

Our roofing page lists CertainTeed Landmark architectural shingles as ASTM D3161 Class F, approved for Miami-Dade, and Class 3 for impact under UL 2218. The manufacturer’s data sheet linked there also lists ASTM D7158 Class H and Florida Product Approval FL5444. Impact class is a separate test from wind, and it’s about hail.

The same data sheet notes that on roofs pitched 2 in 12 up to just under 4 in 12, the shingle needs extra underlayment. Below 2 in 12, shingles aren’t allowed at all.

Why the rating isn’t the whole story

In FEMA’s coastal construction guide, Fact Sheet 7.3 covers asphalt shingles in high wind, and its first point is worth repeating: use wind ratings to choose between shingles, but don’t count on the rating alone for performance. What it recommends instead is mostly about the install:

  • Roofing nails instead of staples, driven properly. FEMA ties correct nail driving directly to blow-off resistance.
  • Nails long enough to come through the underside of the sheathing.
  • Stainless steel nails within 3,000 feet of saltwater.
  • A check after the roof has had enough sun to activate the sealant strips, to confirm the tabs actually sealed down.

The FORTIFIED Roof standard from the Insurance Institute for Business & Home Safety goes further. Its roof requirements call for shingles rated D3161 Class F or D7158 Class H, a fully adhered starter strip, a wider drip edge, ring-shank nails in the deck and a sealed roof deck.

Questions to ask about any shingle quote

  • Which wind class is printed on the wrapper, and does it match the class required for your wind speed?
  • What’s the product approval number?
  • How many nails per shingle, and how is the starter row set at the eaves and rakes?
  • What underlayment goes under it, and is the deck being re-nailed?

We’ll answer each of those on paper for a shingle roof replacement at your house. Our hurricane roofing page covers the rest of the storm details. Call (786) 654-8273.

See your home with impact windows

Pick a window style, a frame color and a front door, and see them on a South Florida home.